Packed Column Injector
WBI – Wide Bore Injector
The WBI is very similar to the Split Injector (SPL) but it has no split outlet. Therefore, when using capillary columns, any splitless liner can be used. However, it is mostly used in combination with glass and stainless-steel (S.S.) packed columns, where a special liner with an internal tapered shape is needed.
Standard recommendation for capillary columns:
227-35008-01 - for standard applications
Specifications & Ordering Information
P/N | Wool | Description | |
---|---|---|---|
227-35008-01 |
|
Yes | Splitless liner; standard deactivated (max. temp. 400 °C); (5 pcs) |
221-48335-01 |
|
No | Splitless Liner; non-deactivated (1 pc) |
Standard recommendation for glass and stainless steel columns:
221-48886 - for standard applications
P/N | Wool | Description | |
---|---|---|---|
221-48886 |
|
Yes | Splitless Liner for glass and S.S. packed columns |
221-48993 |
|
Yes | Splitless liner for glass and S.S. packed columns for operation with TCD |
SINJ – Single Packed Injector
SINJ injectors do not have a split outlet (unlike SPL-injectors) nor septum purge flows (unlike SPL- and WBI-injectors). Consequently, everything that is injected enters the column. It is therefore typically used for packed columns and valve systems.
When using a glass column, one should add a glass liner to prevent the column from accumulating non-volatile components. In some cases, it is already integrated in the column. When using a stainless column, it is always necessary to connect a glass liner to the column at the side of the injection unit.
Specifications & Ordering Information
P/N | Description | |
---|---|---|
221-80902-84 |
|
Liner for glass and S.S. columns SINJ-2030 (5 pcs.) |
221-14093-84 |
|
Liner for glass and S.S. columns with 3.0 – 3.4 mm ID (GC-2014) (5 pcs.) |
221-14094-84 |
|
Liner for glass and S.S. columns with 2.4 – 2.8 mm ID (GC-2014) (5 pcs.) |
WBC Attachment – Wide Bore Column Attachment
It enables the use of packed injectors in combination with wide bore (0.53 mm ID) capillary columns. Special liners with an internal tapered shape are needed, in order to minimize peak tailing.
Specifications & Ordering Information
P/N | Description | |
---|---|---|
221-38107-02 |
|
Glass liner for GC-2030 (1 pc.) |
221-38107-01 |
|
Glass liner for GC-2025 and 2010 Series (1 pc.) |
221-38107 |
|
Glass liner for GC-2014 (1 pc.) |
Neuigkeiten und Veranstaltungen
-
Gaschromatographie (GC) - Grundlagen, Software, Wartungsarbeiten (Berlin)
Eintägiger GC-Kurs für Einsteiger und Wiedereinsteiger zur Grundlagenvermittlung und Auffrischung
Voraussetzung: keine
Ablauf:
Grundlagen der Gaschromatographie
Überblick über die GC-Software LabSolution (Geräteparameter, Methodenentwicklung, Auswertung inkl. Quantifizierung, Reporterstellung)
Arbeiten mit dem GC-2030: Säuleneinbau, einfache Wartungsarbeiten
Tipps & Tricks in der GC
Zertifikate, die als Weiterbildungsnachweis dienen, werden ausgestellt
Personen: 4-6
Preis: 520,00 €
-
Chromatographie (HPLC/GC) Individuelles Kunden-Training
Duisburg oder vor Ort
Inhalt und Dauer: nach Absprache
Preis: auf Anfrage
Rückfragen unter kundenkurse@shimadzu.de
-
Nexis SCD-2030 vereinfacht Komplexität - Weltweit innovativste Lösung für den Schwefelnachweis