Triple Quadrupole LC-MS/MS Comparison
Die Triple-Quadrupol-Massenspektrometrie ist ein vielseitiges Werkzeug für die quantitative Analyse. Erleben Sie die hervorragende Leistungsfähigkeit und Robustheit der LC-MS-Triple-Quadrupol-Geräte von Shimadzu. An Ihre individuelle Analytik angepasst, erfüllen die Systeme Ihre jeweiligen Anforderungen an Geschwindigkeit, Empfindlichkeit und Auflösung und sorgen für ein Höchstmaß an Sicherheit bei Routineanalysen mit hohem Durchsatz und/oder spezielleren Anwendungen.
Vergleichen Sie die Triple-Quadrupol-LC-MS/MS-Systeme von Shimadzu.
Triple Quadrupole LC-MS/MS Comparison
LCMS-8060RX | LCMS-8050RX | LCMS-8045RX | ||
---|---|---|---|---|
Features | The LCMS-8060RX builds on the exceptional sensitivity and UF capabilities of the LCMS-8060NX and adds even more robustness without compromising sensitivity. | Engineered to deliver excellent sensitivity the LCMS-8050RX further extends the performance of the LCMS-8050 to meet the ever-changing needs of any LC-MS/MS laboratory. | Designed for rugged, routine LC-MS/MS analysis with the optimal balance of cost, sensitivity and performance now enhanced with greater robustness and easier to use. | |
Sensitivity (S/N) | ![]() |
![]() |
![]() |
|
Scan Speed | ![]() |
![]() |
![]() |
|
Ionization Unit Compatibility | ESI | |||
APCI |
![]() |
![]() |
![]() |
|
DUIS*1) |
![]() |
![]() |
![]() |
|
Heated-ESI |
![]() |
![]() |
![]() |
|
Heated-ESI with IonFocus |
![]() |
![]() |
![]() |
|
Micro-ESI |
![]() |
![]() |
![]() |
|
Probe-ESI |
![]() |
![]() |
![]() |
|
Measurement Mode | Q1 Scan/SIM |
![]() |
![]() |
![]() |
Q3 Scan/SIM |
![]() |
![]() |
![]() |
|
MRM |
![]() |
![]() |
![]() |
|
Precursor ion scan |
![]() |
![]() |
![]() |
|
Product ion scan |
![]() |
![]() |
![]() |
|
Neutral loss scan |
![]() |
![]() |
![]() |
|
Synchronized Survey Scan™*2) |
![]() |
![]() |
![]() |
|
Collision Cell | UFsweeper™*3) III | UFsweeper III | UFsweeper II | |
QP guard *4) |
![]() |
|||
LCMS-8060RX | LCMS-8050RX | LCMS-8045RX |
- DUIS: The dual ion source continuously performs both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI).
- Synchronized Survey Scan: Synchronized Survey Scan (SSS) automatically performs a product ion scanning whenever a pre-set survey scan threshold is exceeded.
- UFsweeper: UFsweeper is a unique technology that delivers unparalleled efficiency and speed. UFsweeper accelerates ions out of the collision cell by forming a pseudo-potential surface.
- QP guard: Reduces contamination of the quadrupole rod by applying voltage to the multi-pole and preventing unwanted ions from entering the quadrupole rod.
Application Specific LC-MS Systems Products
Neuigkeiten und Veranstaltungen
-
Produktneuheit LCMS-8060NX
-
Probenvorbereitungsmodul: Vollautomatische klinische Probenvorbereitung mit LCMS-Analyse
Laborpraxis
-
CLAM-2030: Vollautomatische klinische Probenvorbereitung mit LCMS-Analyse in einem System
-
Monoklonale Antikörper: schnell und sicher analysiert
LABO
-
Komplettlösung für Therapeutisches Arzneimittel-Monitoring: Vollautomatisierte massenspektrometrische Analyse von Antibiotika im Blut
GIT Laborportal
-
LCMS-9030 Q-TOF - Höchstleistung. Mühelos.