General-Purpose Columns
SH-RtxTM -1
Non-polar phase: CrossbondTM 100% dimethyl polysiloxane
General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates.
Equivalent to USP G1, G2, G38 phases.
Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1
ID
df
Temp. Range
10 m
15 m
20 m
25 m
30 m
60 m
105 m
0.10 mm
0.40 µm
-60 to 330/350°C
-
-
227-36330-01
-
-
-
-
0.25 mm
0.10 µm
-60 to 330/350°C
-
221-75718-15
-
-
221-75718-30
227-36096-01
-
0.25 µm
-60 to 330/350°C
221-75719-10
-
-
221-75719-25
221-75719-30
221-75719-60
-
0.50 µm
-60 to 330/350°C
-
-
-
-
227-36097-01
227-36097-02
-
1.00 µm
-60 to 320/340°C
-
-
-
-
227-36098-01
227-36098-02
221-75721-05
0.32 mm
0.10 µm
-60 to 330/350°C
-
-
-
-
227-36099-01
227-36099-02
-
0.25 µm
-60 to 330/350°C
-
-
-
-
221-75723-30
221-75723-60
-
0.50 µm
-60 to 330/350°C
-
-
-
-
221-75724-30
227-36100-01
-
1.00 µm
-60 to 320/340°C
-
-
-
-
221-75725-30
221-75725-60
-
1.50 µm
-60 to 310/330°C
-
-
-
-
227-36101-01
227-36101-02
-
3.00 µm
-60 to 280/300°C
-
-
-
-
227-36102-01
227-36102-02
-
4.00 µm
-60 to 280/300°C
-
-
-
-
227-36103-01
-
-
5.00 µm
-60 to 260/280°C
-
-
-
-
221-75728-30
221-75728-60
-
0.53 mm
0.10 µm
-60 to 320/340°C
-
-
-
-
227-36104-01
-
-
0.25 µm
-60 to 320/340°C
-
-
-
-
221-75729-30
227-36105-01
-
0.50 µm
-60 to 310/330°C
-
221-75730-15
-
-
221-75730-30
227-36106-01
-
1.00 µm
-60 to 310/330°C
-
221-75731-15
-
-
221-75731-30
221-75731-60
-
1.50 µm
-60 to 310/330°C
-
221-75732-15
-
-
221-75732-30
227-36107-01
-
3.00 µm
-60 to 270/290°C
-
-
-
-
221-75733-30
221-75733-60
-
5.00 µm
-60 to 270/290°C
-
-
-
-
221-75734-30
221-75734-60
-
7.00 µm
-60 to 240/260°C
-
-
-
-
227-36108-01
227-36108-02
-
SH-RtxTM -1 PONA
Compatible with ASTM and CGSB for hydrocarbon analysis.
ID
df
Temp. Range
100 m
0.25 mm
0.50 µm
-60 to 300/340°C
221-76196-00
SH-RtxTM -5
Low-polarity phase: CrossbondxTM 5% diphenyl / 95% dimethyl polysiloxane
General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles.
Equivalent to USP G27 and G36 phases.
Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5
ID
df
Temp. Range
15 m
25 m
30 m
60 m
0.25 mm
0.10 µm
-60 to 330/350°C
221-75700-15
-
221-75700-30
227-36109-01
0.25 µm
-60 to 330/350°C
-
-
221-75701-30
227-36110-01
0.50 µm
-60 to 330/350°C
-
221-76178-25
221-76178-30
227-36111-01
1.00 µm
-60 to 320/340°C
-
-
221-75702-30
227-36112-01
0.32 mm
0.10 µm
-60 to 330/350°C
-
-
227-36113-01
-
0.25 µm
-60 to 330/350°C
221-75703-15
-
221-75703-30
221-75703-60
0.50 µm
-60 to 330/350°C
-
-
221-75704-30
227-36114-01
1.00 µm
-60 to 320/340°C
-
-
221-75705-30
221-75705-60
1.50 µm
-60 to 310/330°C
-
-
221-76181-30
227-36115-01
3.00 µm
-60 to 280/300°C
-
-
227-36116-01
227-36116-02
0.53 mm
0.10 µm
-60 to 320/340°C
-
-
227-36117-01
-
0.25 µm
-60 to 320/340°C
-
-
221-75708-30
227-36118-01
0.50 µm
-60 to 320/330°C
-
-
221-75709-30
227-36119-01
1.00 µm
-60 to 320/330°C
221-75710-15
-
221-75710-30
221-75710-60
1.50 µm
-60 to 310/330°C
221-75711-15
-
221-75711-30
227-36120-01
3.00 µm
-60 to 270/290°C
-
-
221-75712-30
227-36121-01
5.00 µm
-60 to 270/290°C
-
-
221-75713-30
221-75713-60
SH-RtxTM -5 MS
Low-polarity phase: CrossbondTM 5% diphenyl / 95% dimethyl polysiloxane
Column specifically tested for low-bleed performance.
General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles.
Equivalent to USP G27 and G36 phases.
Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5
ID
df
Temp. Range
15 m
30 m
60 m
0.25 mm
0.10 µm
-60 to 330/350°C
221-75854-15
221-75854-30
227-36122-01
0.25 µm
-60 to 330/350°C
221-75855-15
221-75855-30
227-36123-01
0.50 µm
-60 to 330/350°C
-
227-36124-01
227-36124-02
1.00 µm
-60 to 325/350°C
-
221-75857-30
-
0.32 mm
0.10 µm
-60 to 330/350°C
-
227-36125-01
227-36125-02
0.25 µm
-60 to 330/350°C
-
221-75858-30
221-75858-60
0.50 µm
-60 to 330/350°C
-
227-36126-01
227-36126-02
1.00 µm
-60 to 325/350°C
-
227-36127-01
-
0.53 mm
0.50 µm
-60 to 320/340°C
-
221-76191-30
-
1.00 µm
-60 to 320/340°C
-
227-36128-01
-
1.50 µm
-60 to 310/330°C
-
227-36129-01
-
SH-RtxTM -20
Mid-polarity phase: CrossbondTM 20% diphenyl / 80% dimethyl polysiloxane
General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
Equivalent to USP G28 and G32 phases.
Similar phases: SPB-20, 007-20, AT-20, EC-20
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.10 µm
-20 to 300/320°C
227-36130-01
227-36130-02
0.25 µm
-20 to 300/320°C
227-36131-01
227-36131-02
0.50 µm
-20 to 290/310°C
227-36132-01
227-36132-02
1.00 µm
-20 to 280/300°C
227-36133-01
227-36133-02
0.32 mm
0.10 µm
-20 to 300/320°C
227-36134-01
227-36134-02
0.25 µm
-20 to 300/320°C
227-36135-01
227-36135-02
0.50 µm
-20 to 290/310°C
227-36136-01
227-36136-02
1.00 µm
-20 to 280/300°C
227-36137-01
227-36137-02
1.5 µm
-20 to 270/290°C
227-36138-01
227-36138-02
3.0 µm
-20 to 250/270°C
227-36139-01
227-36139-02
0.53 mm
0.10 µm
-20 to 260/280°C
227-36140-01
227-36140-02
0.25 µm
-20 to 260/280°C
-
227-36141-01
0.50 mm
-20 to 260/280°C
227-3142-01
-
1.00 µm
-20 to 260/280°C
227-36143-01
227-36143-02
1.50 µm
-20 to 250/270°C
227-36144-01
-
3.00 µm
-20 to 240/260°C
227-36145-01
227-36145-02
SH-RtxTM -35 / SH-RtxTM -35 MS
Mid-polarity phase: CrossbondTM 35% diphenyl / 65% dimethyl polysiloxane
General-purpose columns for organochlorine pesticides, PCB congeners (e.g., Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
Equivalent to USP G42 phase.
Similar phases: HP-35, DB-35, SPB-35, SPB-608
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.10 µm
40 to 320°C
227-36146-01
227-36146-02
0.25 µm
40 to 320°C
227-36147-01
227-36147-02
0.50 µm
40 to 310°C
227-36148-01
227-36148-02
1.00 µm
40 to 290°C
227-36149-01
227-36149-02
0.32 mm
0.10 µm
40 to 320°C
227-36150-01
227-36150-02
0.25 µm
40 to 320°C
227-36151-01
227-36151-02
0.50 µm
40 to 310°C
227-36152-01
227-36152-02
1.00 µm
40 to 290°C
227-36153-01
227-36153-02
1.5 µm
40 to 270/290°C
227-36154-01
-
3.0 µm
40 to 250/270°C
227-36155-01
227-36155-02
0.53 mm
0.10 µm
40 to 260/280°C
-
227-36156-01
0.25 µm
40 to 260/280°C
-
227-36157-01
0.50 mm
40 to 300°C
227-36158-01
227-36158-02
1.00 µm
40 to 290°C
227-36159-01
227-36159-02
1.50 µm
40 to 280°C
227-36160-01
227-36160-02
3.00 µm
40 to 240/260°C
227-36161-01
227-36161-02
SH-Rtx-35MS (Low-bleed phase for GCMS analysis)
ID
df
Temp. Range
30 m
0.25 mm
0.25 µm
40 to 320°C
221-75835-30
SH-RtxTM -50
Mid-polarity phase: CrossbondTM 100% methyl phenyl polysiloxane
General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols.
Equivalent to USP G3 phase.
Similar phases: HP-50+, CP-Sil 24 CB, SPB-50
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.25 µm
40 to 300/320°C
227-36162-01
227-36162-02
0.50 µm
40 to 290/310°C
227-36163-01
227-36163-02
1.00 µm
40 to 280/300°C
227-36164-01
227-36164-02
0.32 mm
0.25 µm
40 to 300/320°C
221-76182-30
227-36165-01
0.50 µm
40 to 290/310°C
227-36166-01
227-36166-02
1.00 µm
40 to 280/300°C
227-36167-01
227-36167-02
0.53 mm
0.50 mm
40 to 270/290°C
227-36168-01
227-36168-02
0.83 µm
40 to 270/290°C
227-36169-01
-
1.00 µm
40 to 260/280°C
227-36170-01
227-36170-02
1.50 µm
40 to 250/270°C
227-36171-01
227-36171-02
SH-RtxTM -65
Mid-polarity phase: CrossbondTM 65% diphenyl / 35% dimethyl polysiloxane
General-purpose columns for phenols, fatty acids, triglycerides.
Equivalent to USP G17 phase.
ID
df
Temp. Range
30 m
0.25 mm
0.25 µm
50 to 300°C
227-36172-01
0.50 µm
50 to 280/300°C
227-36173-01
1.00 µm
50 to 260/280°C
227-36174-01
0.32 mm
0.25 µm
50 to 300°C
227-36175-01
0.50 µm
50 to 280/300°C
227-36176-01
1.00 µm
50 to 260/280°C
227-36177-01
0.53 mm
1.00 µm
50 to 250/270°C
227-36178-01
SH-RtxTM -1301
Mid-polarity phase: CrossbondTM 6% cyanopropylphenyl / 94% dimethyl polysiloxane
General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds.
Equivalent to USP G43 phase.
Similar phases: DB-1301, CP-1301, SPB-1301
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.25 µm
-20 to 280°C
221-76194-30
221-76194-60
0.50 µm
-20 to 270°C
227-36203-01
-
1.00 µm
-20 to 260°C
227-36204-01
227-36204-02
1.40 µm
-20 to 240°C
-
227-36205-01
0.32 mm
0.25 µm
-20 to 280°C
227-36206-01
227-36206-02
0.50 µm
-20 to 270°C
227-36207-01
227-36207-02
1.00 µm
-20 to 260°C
227-36208-01
227-36208-02
1.50 µm
-20 to 250°C
227-36209-01
227-36209-02
1.80 µm
-20 to 240°C
227-36210-01
227-36210-02
0.53 mm
0.25 µm
-20 to 280°C
227-36211-01
-
0.50 µm
-20 to 270°C
227-36212-01
227-36212-02
1.00 µm
-20 to 260°C
227-36213-01
227-36213-02
1.50 µm
-20 to 250°C
227-36214-01
-
SH-RtxTM -624
Mid-polarity phase: CrossbondTM 6% cyanopropylphenyl / 94% dimethyl polysiloxane
Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
Equivalent to USP G43 phase.
Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
ID
df
Temp. Range
20 m
30 m
60 m
75 m
0.10 mm
0.50 µm
-20 to 240°C
227-36332-01
-
-
-
0.18 mm
1.00 µm
-20 to 240°C
227-36259-01
-
-
-
0.25 mm
1.40 µm
-20 to 240°C
-
221-75863-30
227-36215-01
-
0.32 mm
1.80 µm
-20 to 240°C
-
221-75864-30
221-75864-60
-
0.53 mm
3.00 µm
-20 to 240°C
-
221-75865-30
221-75865-60
221-75865-75
SH-RtxTM -1701
Mid-polarity phase: CrossbondTM 14% cyanopropylphenyl / 86% dimethyl polysiloxane
General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), pesticides, and fragrance compounds.
Equivalent to USP G46 phase.
Similar phases: DB-1701P, DB-1701, CP Sil 19 CB, VF-1701ms, VF-1701 Pesticides, SPB-1701
ID
df
Temp. Range
15 m
30 m
60 m
0.25 mm
0.10 µm
-20 to 280°C
-
227-36216-01
227-36216-02
0.25 µm
-20 to 280°C
-
221-75777-30
227-36217-01
0.50 µm
-20 to 270/280°C
-
221-75778-30
227-36218-01
1.00 µm
-20 to 260/280°C
-
221-75779-30
227-36219-01
0.32 mm
0.10 µm
-20 to 280°C
-
221-76184-30
227-36220-01
0.25 µm
-20 to 280°C
221-75780-15
221-75780-30
221-75780-60
0.50 µm
-20 to 270/280°C
-
221-75781-30
227-36221-01
1.00 µm
-20 to 260/280°C
-
221-75782-30
221-75782-60
1.50 µm
-20 to 240/260°C
-
227-36222-01
227-36222-02
0.53 mm
0.10 µm
-20 to 270/280°C
-
227-36223-01
227-36223-02
0.25 µm
-20 to 270/280°C
-
227-36224-01
-
0.50 µm
-20 to 260/270°C
-
227-36225-01
-
1.00 µm
-20 to 250/270°C
-
221-75785-30
227-36226-01
1.50 µm
-20 to 240/260°C
-
227-36227-01
227-36227-02
3.00 µm
-20 to 230/250°C
-
227-36228-01
227-36228-02
SH-RtxTM -200 / SH-RtxTM -200 MS
Mid-polarity phase: CrossbondTM trifluoropropyl methyl polysiloxane
General-purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, glycols, and drugs of abuse.
Equivalent to USP G6 phase.
Similar phases: DB-210, DB-200, VF-200ms
SH-Rtx-200
ID
df
Temp. Range
30 m
60 m
105 m
0.25 mm
0.10 µm
-20 to 320/340°C
227-36179-01
22736179-02
-
0.25 µm
-20 to 320/340°C
227-36180-01
227-36180-02
-
0.50 µm
-20 to 310/330°C
227-36181-01
227-36181-02
-
1.00 µm
-20 to 290/310°C
221-75800-30
227-36182-01
-
0.32 mm
0.10 µm
-20 to 320/340°C
227-36183-01
227-36183-02
-
0.25 µm
-20 to 320/340°C
227-36184-01
227-36184-02
-
0.50 µm
-20 to 310/330°C
227-35185-01
227-36185-02
-
1.00 µm
-20 to 290/310°C
227-36186-01
227-36186-02
-
1.50 µm
-20 to 280/310°C
227-36187-01
227-36187-02
221-75804-15
0.53 mm
0.10 µm
-20 to 310/330°C
227-36188-01
227-36188-02
-
0.25 µm
-20 to 310/330°C
227-36189-01
227-36189-02
-
0.50 µm
-20 to 300/320°C
227-36190-01
227-36190-02
-
1.00 µm
-20 to 290/310°C
227-36191-01
227-36191-02
-
1.50 µm
-20 to 280/300°C
227-36192-01
227-36192-02
-
3.00 µm
-20 to 260/380°C
227-36193-01
227-36193-02
-
SH-Rtx-200MS (Low-bleed phase for GCMS analysis)
ID
df
Temp. Range
30 m
0.25 mm
0.10 µm
-20 to 320/340°C
227-36194-01
0.25 µm
-20 to 320/340°C
221-75811-30
0.50 µm
-20 to 310/330°C
227-36195-01
1.00 µm
-20 to 290/310°C
227-36196-01
0.32 mm
0.10 µm
-20 to 320/340°C
227-36197-01
0.25 µm
-20 to 320/340°C
221-75814-30
0.50 µm
-20 to 310/330°C
227-36198-01
1.00 µm
-20 to 290/310°C
227-36199-01
0.53 mm
0.50 µm
-20 to 300/320°C
227-36200-01
1.00 µm
-20 to 290/310°C
227-36201-01
1.50 µm
-20 to 290/310°C
227-36202-01
SH-RtxTM -225
Polar phase: CrossbondTM 50% cyanopropylmethyl / 50% phenylmethyl polysiloxane
General-purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.
Equivalent to USP G7 and G19 phases.
Similar phases: DB-225, DB-225MS, CP-Sil 43 CB, SPB-225
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.25 µm
40 to 220/240°C
227-36229-01
227-36229-02
0.50 µm
40 to 220/240°C
227-36230-01
-
0.32 mm
0.10 µm
40 to 220/240°C
227-36231-01
-
0.25 µm
40 to 220/240°C
227-36232-01
-
0.50 µm
40 to 220/240°C
227-36233-01
-
1.00 µm
40 to 200/220°C
227-36234-01
227-36234-02
0.53 mm
0.25 µm
40 to 200/220°C
227-36235-01
-
0.50 µm
40 to 200/220°C
227-36236-01
-
1.00 µm
40 to 200/220°C
227-36237-01
-
SH-RtxTM -2330
Highly polar phase: CrossbondTM 90% biscyanopropyl / 10% cyanopropylphenyl polysiloxane (Non-bonded)
General-purpose columns for cis/trans FAMEs, dioxin isomers.
Equivalent to USP G8 and G48 phase.
Similar phases: DB-23, VF-23ms, SP-2330, SP-2331, SP-2380
ID
df
Temp. Range
30 m
60 m
0.25 mm
0.10 µm
0 to 260/275°C
227-36238-01
227-36238-02
0.20 µm
0 to 260/275°C
227-36239-01
227-36239-02
0.32 mm
0.10 µm
0 to 260/275°C
227-36240-01
227-36240-02
0.20 µm
0 to 260/275°C
227-36241-01
227-36241-02
0.53 mm
0.10 µm
0 to 260/275°C
-
227-36242-01
0.20 µm
0 to 260/275°C
227-36243-01
227-36243-02
SH-RtxTM -Wax
Polar phase: CrossbondTM polyethylene glycol
Best polyethylene glycol (PEG) phase for alkenols, glycols, and aldehydes.
Equivalent to USP G14, G15, G16, G20, G39 phases.
Similar phases: DB-Wax, CP-Wax 52 CB
ID
df
Temp. Range
20 m
30 m
50 m
60 m
0.25 mm
0.10 µm
20 to 250°C
-
221-76186-30
-
-
0.25 µm
20 to 250°C
-
221-75893-30
221-75893-50
221-75893-60
0.50 µm
20 to 250°C
-
221-75894-30
-
221-75894-60
0.32 mm
0.25 µm
20 to 250°C
221-75895-20
221-75895-30
-
221-75895-60
0.50 µm
20 to 250°C
-
221-75896-30
221-75896-50
221-75896-60
1.00 µm
20 to 240/250°C
-
221-75897-30
-
221-75897-60
0.53 mm
0.25 µm
20 to 250°C
-
227-36244-01
-
-
0.50 µm
20 to 250°C
-
221-76188-30
-
227-36245-01
1.00 µm
20 to 240/250°C
-
221-75899-30
-
221-75899-60
SH-StabilwaxTM
Polar phase: CrossbondTM polyethylene glycol
Low-bleed PEG column ensures long column lifetimes.
Rugged enough to withstand repeated water injections.
Equivalent to USP G14, G15, G16, G20, and G39 phases.
Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10
ID
df
Temp. Range
30 m
50 m
60 m
0.25 mm
0.10 µm
40 to 250/260°C
227-36246-01
-
227-36246-02
0.25 µm
40 to 250/260°C
227-36305-02
227-36247-01
227-36247-02
0.50 µm
40 to 250/260°C
227-36248-01
-
227-36248-02
0.32 mm
0.10 µm
40 to 250/260°C
227-36249-01
-
227-36249-02
0.25 µm
40 to 250/260°C
221-75972-30
-
227-36250-01
0.50 µm
40 to 250/260°C
227-36251-01
-
221-75975-60
1.00 µm
40 to 240/250°C
227-36252-01
-
227-36252-02
0.53 mm
0.10 µm
40 to 250/260°C
227-36253-01
-
-
0.25 µm
40 to 250/260°C
227-36254-01
-
227-36254-02
0.50 µm
40 to 250/260°C
227-36255-01
-
227-36255-02
1.00 µm
40 to 240/250°C
221-75979-30
-
227-36256-01
1.50 µm
40 to 230/240°C
227-36257-01
-
227-36257-02
2.00 µm
40 to 220/230°C
227-36258-01
-
-
For Research Use Only. Not for use in diagnostic procedures.
This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.