SH-RtxTM-1

  • Non-polar phase: CrossbondTM 100% dimethyl polysiloxane
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semi-volatiles, pesticides, oxygenates.
  • Equivalent to USP G1, G2, G38 phases.
  • Similar phases: HP-1, DB-1, CP Sil 5 CB, SPB-1
ID df Temp. Range 10 m 15 m 20 m 25 m 30 m 60 m 105 m
0.10 mm 0.40 µm -60 to 330/350°C - - 227-36330-01 - - - -
0.25 mm 0.10 µm -60 to 330/350°C - 221-75718-15 - - 221-75718-30 227-36096-01 -
0.25 µm -60 to 330/350°C 221-75719-10 - - 221-75719-25 221-75719-30 221-75719-60 -
0.50 µm -60 to 330/350°C - - - - 227-36097-01 227-36097-02 -
1.00 µm -60 to 320/340°C - - - - 227-36098-01 227-36098-02 221-75721-05
0.32 mm 0.10 µm -60 to 330/350°C - - - - 227-36099-01 227-36099-02 -
0.25 µm -60 to 330/350°C - - - - 221-75723-30 221-75723-60 -
0.50 µm -60 to 330/350°C - - - - 221-75724-30 227-36100-01 -
1.00 µm -60 to 320/340°C - - - - 221-75725-30 221-75725-60 -
1.50 µm -60 to 310/330°C - - - - 227-36101-01 227-36101-02 -
3.00 µm -60 to 280/300°C - - - - 227-36102-01 227-36102-02 -
4.00 µm -60 to 280/300°C - - - - 227-36103-01 - -
5.00 µm -60 to 260/280°C - - - - 221-75728-30 221-75728-60 -
0.53 mm 0.10 µm -60 to 320/340°C - - - - 227-36104-01 - -
0.25 µm -60 to 320/340°C - - - - 221-75729-30 227-36105-01 -
0.50 µm -60 to 310/330°C - 221-75730-15 - - 221-75730-30 227-36106-01 -
1.00 µm -60 to 310/330°C - 221-75731-15 - - 221-75731-30 221-75731-60 -
1.50 µm -60 to 310/330°C - 221-75732-15 - - 221-75732-30 227-36107-01 -
3.00 µm -60 to 270/290°C - - - - 221-75733-30 221-75733-60 -
5.00 µm -60 to 270/290°C - - - - 221-75734-30 221-75734-60 -
7.00 µm -60 to 240/260°C - - - - 227-36108-01 227-36108-02 -
 
 

SH-RtxTM-1 PONA

  • Compatible with ASTM and CGSB for hydrocarbon analysis.
ID df Temp. Range 100 m
0.25 mm 0.50 µm -60 to 300/340°C 221-76196-00
 
 
 
 

SH-RtxTM-5

  • Low-polarity phase: CrossbondxTM 5% diphenyl / 95% dimethyl polysiloxane
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles.
  • Equivalent to USP G27 and G36 phases.
  • Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5
ID df Temp. Range 15 m 25 m 30 m 60 m
0.25 mm 0.10 µm -60 to 330/350°C 221-75700-15 - 221-75700-30 227-36109-01
0.25 µm -60 to 330/350°C - - 221-75701-30 227-36110-01
0.50 µm -60 to 330/350°C - 221-76178-25 221-76178-30 227-36111-01
1.00 µm -60 to 320/340°C - - 221-75702-30 227-36112-01
0.32 mm 0.10 µm -60 to 330/350°C - - 227-36113-01 -
0.25 µm -60 to 330/350°C 221-75703-15 - 221-75703-30 221-75703-60
0.50 µm -60 to 330/350°C - - 221-75704-30 227-36114-01
1.00 µm -60 to 320/340°C - - 221-75705-30 221-75705-60
1.50 µm -60 to 310/330°C - - 221-76181-30 227-36115-01
3.00 µm -60 to 280/300°C - - 227-36116-01 227-36116-02
0.53 mm 0.10 µm -60 to 320/340°C - - 227-36117-01 -
0.25 µm -60 to 320/340°C - - 221-75708-30 227-36118-01
0.50 µm -60 to 320/330°C - - 221-75709-30 227-36119-01
1.00 µm -60 to 320/330°C 221-75710-15 - 221-75710-30 221-75710-60
1.50 µm -60 to 310/330°C 221-75711-15 - 221-75711-30 227-36120-01
3.00 µm -60 to 270/290°C - - 221-75712-30 227-36121-01
5.00 µm -60 to 270/290°C - - 221-75713-30 221-75713-60
 
 
 
 

SH-RtxTM-5 MS

  • Low-polarity phase: CrossbondTM 5% diphenyl / 95% dimethyl polysiloxane
  • Column specifically tested for low-bleed performance.
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semi-volatiles.
  • Equivalent to USP G27 and G36 phases.
  • Similar phases: HP-5, DB-5, CP Sil 8 CB, SPB-5
ID df Temp. Range 15 m 30 m 60 m
0.25 mm 0.10 µm -60 to 330/350°C 221-75854-15 221-75854-30 227-36122-01
0.25 µm -60 to 330/350°C 221-75855-15 221-75855-30 227-36123-01
0.50 µm -60 to 330/350°C - 227-36124-01 227-36124-02
1.00 µm -60 to 325/350°C - 221-75857-30 -
0.32 mm 0.10 µm -60 to 330/350°C - 227-36125-01 227-36125-02
0.25 µm -60 to 330/350°C - 221-75858-30 221-75858-60
0.50 µm -60 to 330/350°C - 227-36126-01 227-36126-02
1.00 µm -60 to 325/350°C - 227-36127-01 -
0.53 mm 0.50 µm -60 to 320/340°C - 221-76191-30 -
1.00 µm -60 to 320/340°C - 227-36128-01 -
1.50 µm -60 to 310/330°C - 227-36129-01 -
 
 
 

SH-RtxTM-20

  • Mid-polarity phase: CrossbondTM 20% diphenyl / 80% dimethyl polysiloxane
  • General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
  • Equivalent to USP G28 and G32 phases.
  • Similar phases: SPB-20, 007-20, AT-20, EC-20
ID df Temp. Range 30 m 60 m
0.25 mm 0.10 µm -20 to 300/320°C 227-36130-01 227-36130-02
0.25 µm -20 to 300/320°C 227-36131-01 227-36131-02
0.50 µm -20 to 290/310°C 227-36132-01 227-36132-02
1.00 µm -20 to 280/300°C 227-36133-01 227-36133-02
0.32 mm 0.10 µm -20 to 300/320°C 227-36134-01 227-36134-02
0.25 µm -20 to 300/320°C 227-36135-01 227-36135-02
0.50 µm -20 to 290/310°C 227-36136-01 227-36136-02
1.00 µm -20 to 280/300°C 227-36137-01 227-36137-02
1.5 µm -20 to 270/290°C 227-36138-01 227-36138-02
3.0 µm -20 to 250/270°C 227-36139-01 227-36139-02
0.53 mm 0.10 µm -20 to 260/280°C 227-36140-01 227-36140-02
0.25 µm -20 to 260/280°C - 227-36141-01
0.50 mm -20 to 260/280°C 227-3142-01 -
1.00 µm -20 to 260/280°C 227-36143-01 227-36143-02
1.50 µm -20 to 250/270°C 227-36144-01 -
3.00 µm -20 to 240/260°C 227-36145-01 227-36145-02
 
 
 

SH-RtxTM-35 / SH-RtxTM-35 MS

  • Mid-polarity phase: CrossbondTM 35% diphenyl / 65% dimethyl polysiloxane
  • General-purpose columns for organochlorine pesticides, PCB congeners (e.g., Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
  • Equivalent to USP G42 phase.
  • Similar phases: HP-35, DB-35, SPB-35, SPB-608 

SH-Rtx-35

ID df Temp. Range 30 m 60 m
0.25 mm 0.10 µm 40 to 320°C 227-36146-01 227-36146-02
0.25 µm 40 to 320°C 227-36147-01 227-36147-02
0.50 µm 40 to 310°C 227-36148-01 227-36148-02
1.00 µm 40 to 290°C 227-36149-01 227-36149-02
0.32 mm 0.10 µm 40 to 320°C 227-36150-01 227-36150-02
0.25 µm 40 to 320°C 227-36151-01 227-36151-02
0.50 µm 40 to 310°C 227-36152-01 227-36152-02
1.00 µm 40 to 290°C 227-36153-01 227-36153-02
1.5 µm 40 to 270/290°C 227-36154-01 -
3.0 µm 40 to 250/270°C 227-36155-01 227-36155-02
0.53 mm 0.10 µm 40 to 260/280°C - 227-36156-01
0.25 µm 40 to 260/280°C - 227-36157-01
0.50 mm 40 to 300°C 227-36158-01 227-36158-02
1.00 µm 40 to 290°C 227-36159-01 227-36159-02
1.50 µm 40 to 280°C 227-36160-01 227-36160-02
3.00 µm 40 to 240/260°C 227-36161-01 227-36161-02
 
 

SH-Rtx-35MS (Low-bleed phase for GCMS analysis)

ID df Temp. Range 30 m
0.25 mm 0.25 µm 40 to 320°C 221-75835-30
 
 
 
 

SH-RtxTM-50

  • Mid-polarity phase: CrossbondTM 100% methyl phenyl polysiloxane
  • General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols.
  • Equivalent to USP G3 phase.
  • Similar phases: HP-50+, CP-Sil 24 CB, SPB-50
 
ID df Temp. Range 30 m 60 m
0.25 mm 0.25 µm 40 to 300/320°C 227-36162-01 227-36162-02
0.50 µm 40 to 290/310°C 227-36163-01 227-36163-02
1.00 µm 40 to 280/300°C 227-36164-01 227-36164-02
0.32 mm 0.25 µm 40 to 300/320°C 221-76182-30 227-36165-01
0.50 µm 40 to 290/310°C 227-36166-01 227-36166-02
1.00 µm 40 to 280/300°C 227-36167-01 227-36167-02
0.53 mm 0.50 mm 40 to 270/290°C 227-36168-01 227-36168-02
0.83 µm 40 to 270/290°C 227-36169-01 -
1.00 µm 40 to 260/280°C 227-36170-01 227-36170-02
1.50 µm 40 to 250/270°C 227-36171-01 227-36171-02
 
 
 
 

SH-RtxTM-65

  • Mid-polarity phase: CrossbondTM 65% diphenyl / 35% dimethyl polysiloxane
  • General-purpose columns for phenols, fatty acids, triglycerides.
  • Equivalent to USP G17 phase.
 
ID df Temp. Range 30 m
0.25 mm 0.25 µm 50 to 300°C 227-36172-01
0.50 µm 50 to 280/300°C 227-36173-01
1.00 µm 50 to 260/280°C 227-36174-01
0.32 mm 0.25 µm 50 to 300°C 227-36175-01
0.50 µm 50 to 280/300°C 227-36176-01
1.00 µm 50 to 260/280°C 227-36177-01
0.53 mm 1.00 µm 50 to 250/270°C 227-36178-01
 
 
 
 

SH-RtxTM-1301

  • Mid-polarity phase: CrossbondTM 6% cyanopropylphenyl / 94% dimethyl polysiloxane
  • General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds.
  • Equivalent to USP G43 phase.
  • Similar phases: DB-1301, CP-1301, SPB-1301
ID df Temp. Range 30 m 60 m
0.25 mm 0.25 µm -20 to 280°C 221-76194-30 221-76194-60
0.50 µm -20 to 270°C 227-36203-01 -
1.00 µm -20 to 260°C 227-36204-01 227-36204-02
1.40 µm -20 to 240°C - 227-36205-01
0.32 mm 0.25 µm -20 to 280°C 227-36206-01 227-36206-02
0.50 µm -20 to 270°C 227-36207-01 227-36207-02
1.00 µm -20 to 260°C 227-36208-01 227-36208-02
1.50 µm -20 to 250°C 227-36209-01 227-36209-02
1.80 µm -20 to 240°C 227-36210-01 227-36210-02
0.53 mm 0.25 µm -20 to 280°C 227-36211-01 -
0.50 µm -20 to 270°C 227-36212-01 227-36212-02
1.00 µm -20 to 260°C 227-36213-01 227-36213-02
1.50 µm -20 to 250°C 227-36214-01 -
 
 
 
 

SH-RtxTM-624

  • Mid-polarity phase: CrossbondTM 6% cyanopropylphenyl / 94% dimethyl polysiloxane
  • Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
  • Equivalent to USP G43 phase.
  • Similar phases: HP-624, DB-624, DB-624 UI, VF-624ms, SPB-1301
ID df Temp. Range 20 m 30 m 60 m 75 m
0.10 mm 0.50 µm -20 to 240°C 227-36332-01 - - -
0.18 mm 1.00 µm -20 to 240°C 227-36259-01 - - -
0.25 mm 1.40 µm -20 to 240°C - 221-75863-30 227-36215-01 -
0.32 mm 1.80 µm -20 to 240°C - 221-75864-30 221-75864-60 -
0.53 mm 3.00 µm -20 to 240°C - 221-75865-30 221-75865-60 221-75865-75
 
 
 
 

SH-RtxTM-1701

  • Mid-polarity phase: CrossbondTM 14% cyanopropylphenyl / 86% dimethyl polysiloxane
  • General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), pesticides, and fragrance compounds.
  • Equivalent to USP G46 phase.
  • Similar phases: DB-1701P, DB-1701, CP Sil 19 CB, VF-1701ms, VF-1701 Pesticides, SPB-1701
ID df Temp. Range 15 m 30 m 60 m
0.25 mm 0.10 µm -20 to 280°C - 227-36216-01 227-36216-02
0.25 µm -20 to 280°C - 221-75777-30 227-36217-01
0.50 µm -20 to 270/280°C - 221-75778-30 227-36218-01
1.00 µm -20 to 260/280°C - 221-75779-30 227-36219-01
0.32 mm 0.10 µm -20 to 280°C - 221-76184-30 227-36220-01
0.25 µm -20 to 280°C 221-75780-15 221-75780-30 221-75780-60
0.50 µm -20 to 270/280°C - 221-75781-30 227-36221-01
1.00 µm -20 to 260/280°C - 221-75782-30 221-75782-60
1.50 µm -20 to 240/260°C - 227-36222-01 227-36222-02
0.53 mm 0.10 µm -20 to 270/280°C - 227-36223-01 227-36223-02
0.25 µm -20 to 270/280°C - 227-36224-01 -
0.50 µm -20 to 260/270°C - 227-36225-01 -
1.00 µm -20 to 250/270°C - 221-75785-30 227-36226-01
1.50 µm -20 to 240/260°C - 227-36227-01 227-36227-02
3.00 µm -20 to 230/250°C - 227-36228-01 227-36228-02
 
 
 
 

SH-RtxTM-200 / SH-RtxTM-200 MS

  • Mid-polarity phase: CrossbondTM trifluoropropyl methyl polysiloxane
  • General-purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, glycols, and drugs of abuse.
  • Equivalent to USP G6 phase.
  • Similar phases: DB-210, DB-200, VF-200ms

SH-Rtx-200

ID df Temp. Range 30 m 60 m 105 m
0.25 mm 0.10 µm -20 to 320/340°C 227-36179-01 22736179-02 -
0.25 µm -20 to 320/340°C 227-36180-01 227-36180-02 -
0.50 µm -20 to 310/330°C 227-36181-01 227-36181-02 -
1.00 µm -20 to 290/310°C 221-75800-30 227-36182-01 -
0.32 mm 0.10 µm -20 to 320/340°C 227-36183-01 227-36183-02 -
0.25 µm -20 to 320/340°C 227-36184-01 227-36184-02 -
0.50 µm -20 to 310/330°C 227-35185-01 227-36185-02 -
1.00 µm -20 to 290/310°C 227-36186-01 227-36186-02 -
1.50 µm -20 to 280/310°C 227-36187-01 227-36187-02 221-75804-15
0.53 mm 0.10 µm -20 to 310/330°C 227-36188-01 227-36188-02 -
0.25 µm -20 to 310/330°C 227-36189-01 227-36189-02 -
0.50 µm -20 to 300/320°C 227-36190-01 227-36190-02 -
1.00 µm -20 to 290/310°C 227-36191-01 227-36191-02 -
1.50 µm -20 to 280/300°C 227-36192-01 227-36192-02 -
3.00 µm -20 to 260/380°C 227-36193-01 227-36193-02 -
 

SH-Rtx-200MS (Low-bleed phase for GCMS analysis)

ID df Temp. Range 30 m
0.25 mm 0.10 µm -20 to 320/340°C 227-36194-01
0.25 µm -20 to 320/340°C 221-75811-30
0.50 µm -20 to 310/330°C 227-36195-01
1.00 µm -20 to 290/310°C 227-36196-01
0.32 mm 0.10 µm -20 to 320/340°C 227-36197-01
0.25 µm -20 to 320/340°C 221-75814-30
0.50 µm -20 to 310/330°C 227-36198-01
1.00 µm -20 to 290/310°C 227-36199-01
0.53 mm 0.50 µm -20 to 300/320°C 227-36200-01
1.00 µm -20 to 290/310°C 227-36201-01
1.50 µm -20 to 290/310°C 227-36202-01
 
 
 
 

SH-RtxTM-225

  • Polar phase: CrossbondTM 50% cyanopropylmethyl / 50% phenylmethyl polysiloxane
  • General-purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.
  • Equivalent to USP G7 and G19 phases.
  • Similar phases: DB-225, DB-225MS, CP-Sil 43 CB, SPB-225
ID df Temp. Range 30 m 60 m
0.25 mm 0.25 µm 40 to 220/240°C 227-36229-01 227-36229-02
0.50 µm 40 to 220/240°C 227-36230-01 -
0.32 mm 0.10 µm 40 to 220/240°C 227-36231-01 -
0.25 µm 40 to 220/240°C 227-36232-01 -
0.50 µm 40 to 220/240°C 227-36233-01 -
1.00 µm 40 to 200/220°C 227-36234-01 227-36234-02
0.53 mm 0.25 µm 40 to 200/220°C 227-36235-01 -
0.50 µm 40 to 200/220°C 227-36236-01 -
1.00 µm 40 to 200/220°C 227-36237-01 -
 
 
 
 

SH-RtxTM-2330

  • Highly polar phase: CrossbondTM 90% biscyanopropyl / 10% cyanopropylphenyl polysiloxane (Non-bonded)
  • General-purpose columns for cis/trans FAMEs, dioxin isomers.
  • Equivalent to USP G8 and G48 phase.
  • Similar phases: DB-23, VF-23ms, SP-2330, SP-2331, SP-2380
ID df Temp. Range 30 m 60 m
0.25 mm 0.10 µm 0 to 260/275°C 227-36238-01 227-36238-02
0.20 µm 0 to 260/275°C 227-36239-01 227-36239-02
0.32 mm 0.10 µm 0 to 260/275°C 227-36240-01 227-36240-02
0.20 µm 0 to 260/275°C 227-36241-01 227-36241-02
0.53 mm 0.10 µm 0 to 260/275°C - 227-36242-01
0.20 µm 0 to 260/275°C 227-36243-01 227-36243-02
 
 
 
 

SH-RtxTM-Wax

  • Polar phase: CrossbondTM polyethylene glycol
  • Best polyethylene glycol (PEG) phase for alkenols, glycols, and aldehydes.
  • Equivalent to USP G14, G15, G16, G20, G39 phases.
  • Similar phases: DB-Wax, CP-Wax 52 CB
ID df Temp. Range 20 m 30 m 50 m 60 m
0.25 mm 0.10 µm 20 to 250°C - 221-76186-30 - -
0.25 µm 20 to 250°C - 221-75893-30 221-75893-50 221-75893-60
0.50 µm 20 to 250°C - 221-75894-30 - 221-75894-60
0.32 mm 0.25 µm 20 to 250°C 221-75895-20 221-75895-30 - 221-75895-60
0.50 µm 20 to 250°C - 221-75896-30 221-75896-50 221-75896-60
1.00 µm 20 to 240/250°C - 221-75897-30 - 221-75897-60
0.53 mm 0.25 µm 20 to 250°C - 227-36244-01 - -
0.50 µm 20 to 250°C - 221-76188-30 - 227-36245-01
1.00 µm 20 to 240/250°C - 221-75899-30 - 221-75899-60
 
 
 
 

SH-StabilwaxTM

  • Polar phase: CrossbondTM polyethylene glycol
  • Low-bleed PEG column ensures long column lifetimes.
  • Rugged enough to withstand repeated water injections.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.
  • Similar phases: Innowax, CP-Wax 52 CB, VF-WAX MS, Supelcowax-10
ID df Temp. Range 30 m 50 m 60 m
0.25 mm 0.10 µm 40 to 250/260°C 227-36246-01 - 227-36246-02
0.25 µm 40 to 250/260°C 227-36305-02 227-36247-01 227-36247-02
0.50 µm 40 to 250/260°C 227-36248-01 - 227-36248-02
0.32 mm 0.10 µm 40 to 250/260°C 227-36249-01 - 227-36249-02
0.25 µm 40 to 250/260°C 221-75972-30 - 227-36250-01
0.50 µm 40 to 250/260°C 227-36251-01 - 221-75975-60
1.00 µm 40 to 240/250°C 227-36252-01 - 227-36252-02
0.53 mm 0.10 µm 40 to 250/260°C 227-36253-01 - -
0.25 µm 40 to 250/260°C 227-36254-01 - 227-36254-02
0.50 µm 40 to 250/260°C 227-36255-01 - 227-36255-02
1.00 µm 40 to 240/250°C 221-75979-30 - 227-36256-01
1.50 µm 40 to 230/240°C 227-36257-01 - 227-36257-02
2.00 µm 40 to 220/230°C 227-36258-01 - -

For Research Use Only. Not for use in diagnostic procedures.